Product: 5/4 NT3 Boards, 7-1/4 inch (184 mm) width. Type: Select Cedarmill 12 inches (305 mm) with 10-3/4 inches (273 mm) exposure. Product: 4/4 Boards, 7-1/4 inch (184 mm) width. Do not install that product remains in contact with standing water. Never use continuous-edge diamond blades, abrasive discs, or high tooth count circular saw blades 9 Caution: Tools and blades designed to reduce breathable silica do not always result in safe levels by themselves. Irregularities in framing and sheathing can mirror through the finished application. Factory Finish: Refer to Exterior Finish Schedule. Fiber Cement Rustic Grain Trim Board. Vented Soffit Panels: HardieSoffit HZ10 VentedPlus Panels. Type: HardieShingle Individual Shingles 12 inches (305 mm) wide by 18 inches (457 mm) high with 8 inches (203 mm) exposure. These values can be found in the Technical Bulletin "Expansion Characteristics of James Hardie Siding Products" at www.jameshardie.com. Wood Framing: 0.091 inch (2.3 mm) shank by 0.221 inch (5.6 mm) head by 1-1/2 inches (38 mm) corrosion resistant siding nails. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, where not feasible, use a HardieBlade, and dust-reducing circular saw attached to a HEPA vacuum; (3) warn others in the immediate area; (4) wear a properly-fitted, NIOSH-approved dust mask or respirator (e.g. Install metal Z flashing and provide a 1/4 inch (6 mm) gap at horizontal panel joints. Density: Less than 83 pounds per sq ft (4 kPa). Install water barriers and air barriers as required by local building codes. Base Inside Corner Trim: To be used as an inside corner connection for Base trim. Starting: Install a minimum 1/4 inch (6 mm) thick lath starter strip at the bottom course of the wall. Type: Hardie Architectural Multi-Groove Panel 4 by 8 feet (1219 by 2438 mm). at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements. Installer Qualifications: Minimum of 2 years' experience with installation of similar products. See General Fastening Requirements. Provide quantities as recommended by manufacturer. Minimum 1-1/2 inches (38 mm) face and straight, true, of uniform dimensions and properly aligned. 3).When installing corners or other vertical trim, position boards on the wall and attach (fig. Fastening instructions are similar for all applications. Install water-resistive barriers and claddings to dry surfaces. Wood Framing: No. Place fasteners no closer than 3/8 inch (9.5 mm) from panel edges and 2 inches (51 mm) from panel corners. Many other factors can influence dust exposure including jobsite ventilation, the amount of material being cut and breathing protection being used. If installing James Hardie siding products with ColorPlus Technology, leave the protective laminate film in place while cutting. 11 gauge 1-1/4 inches (32 mm) corrosion resistant roofing nails. 2X Smooth HardieTrim manufactured by James Hardie Building Products, Inc. HardieTrim HZ10 Crown moulding manufactured by James Hardie Building Products, Inc. Wood Framing: 4d common corrosion resistant nails. Product: 4/4 Boards, 11-1/4 inch (286 mm) width. Section R703.10.1 as ASTM C 1186 Grade II, Type A Fiber Cement: 2009, 2012, 2015, and 2018. Product: ColorPlus Technology by James Hardie. ASTM D3359 - Standard Test Method for Measuring Adhesion by Tape Test, Tool and Tape. 78-89, Products Installation Guide_HardieSoffit pg. Install materials in strict accordance with manufacturer's installation instructions. HardiePanel HZ10 vertical siding for 30 years. Drive fasteners perpendicular to siding and framing. INSTALLATION - HARDIESOFFIT HZ10 AND VENTED PANELS. 101-107, Products Installation Guide_HardieShingle pg. Allow 1/8 inch gap between trim and siding. Vents can be installed into non-vented soffit. 280154) and Corner Tabs (JH sku no. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for 1 fOreword Telephone directo ry Technical Services 800-942-7343 Tech Barn for Samples and Literature 866-975-8822 Warranty 866-375-8603 Installation Guide James Hardie Products James Hardie, the world leader in the manufacturing and development of fiber-cement building products, has produced this Installation Guide to help builders and contractors with the installation of James Hardie siding and trim products, including James Hardie products with ColorPlus Technology. Store siding on edge or lay flat on a smooth level surface. Vertical Siding: HardiePanel HZ10 siding as manufactured by James Hardie Building Products, Inc. Insect screen can be installed using construction adhesive. Use 16 ga. galvanized 2" long nish nails to ensure proper fastening if needed. James Hardie does manufacture HardieWrap Weather Barrier, a non-woven non-perforated housewrap, which complies with building code requirements. Install flashing around all wall openings. the lowest respirable dust exposures), James Hardie recommends using Best cutting methods and tools whenever possible. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. 4/4, 5/4 Listones de Acabado VIGENTE DESDE SEPTIEMBRE DEL 2013 REQUISITOS DE INSTALACIN - PRODUCTOS CON PRIMER Y COLORPLUS Visite www.jameshardie.com para obtener la versin ms reciente. Type: Hardie Architectural Knockdown Panel4 by 12 feet (1219 by 3658 mm). 8-18 by 0.323 inch (8.2 mm) head self-drilling, corrosion resistant ribbed buglehead screws. Maintain a minimum 1 inch (25 mm) gap between end caps and siding and trim. Type: Smooth, 16 inches (406 mm) by 12 feet (3658 mm. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Sign in to see pricing and availability which varies by market, Resists cracking and splitting from hot humid summer conditions, Superior performance in high wind and hurricane areas. closer than 1/2" from the edges of the trim and for all other fasteners no closer than 3/4". Follow paint manufacturer's written product recommendation and written application instructions. Type: Hardie Architectural Panels - Fine Sand 4 by 8 feet (1219 by 2438 mm). Smoke Developed Index: 0. Prior 8 Tools for Cutting and Fastening Fiber-Cement Products TIP: For the smoothest cuts, when cutting James Hardie siding products with a shear or circular saw, cut the board face down. Set up all cutting tables or workstations in well-ventilated outdoor areas so that any generated dust is carried safely away from workers. Thickness: Plus or minus 0.04 inch (1 mm). 2022 BMC Stock Holdings, Inc. All Rights Reserved. do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. touch-up while the laminate sheet is in place. Type: Texture 5-1/4 inches (133 mm) with 4 inches (102 mm) exposure. Type: HardieShingle Straight-Edge Notched Panel 48 inches (1219 mm) wide by 16 inches (406mm) high with 7 inches (178 mm) exposure. 4). Type: Sierra 8 inches (203 mm) Vertical siding panel 4 feet by 10 feet (1219 mm by 3048 mm). Locate splices at least 12 inches (305 mm) away from window and door openings. Wood Framing: 8d box ring common corrosion resistant nails. The HZ10 product line was engineered for areas with hurricane-force winds, salty sea air from the coast, and the brutal humidity of the Deep South. products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational, sources. Repair any punctures or tears in the water-resistive barrier prior to the installation of the siding. (Figure 29) Terminate ends of the Band Board into Trim or Siding or miter cut the edges of the trim at the corners of the building. Metal Framing: 1-5/8 inches (41 mm) No. 11 gauge 1-1/2 inches (38 mm) corrosion resistant roofing nails. Type: Smooth, 12 inches (305 mm) by 12 feet (3658 mm). May be used in ASTM E119 fire resistance rated assemblies as listed by Warnock Hersey. If uncertain about exposure or protection in a specific situation, always consult a qualified industrial hygienist to determine actual exposure levels. Type: Texture 7-1/4 inches (184 mm) with 6 inches (152 mm) exposure. Never use high-speed power tools when cutting James Hardie products indoors. Protection: Factory applied finish protection such as plastic laminate that is removed once siding is installed. Type: Texture 8-1/4 inches (210 mm) with 7 inches (178 mm) exposure. The Flat Tabs should be attached to the trim in an alternating pattern to the top and bottom of the band board (Figure 30 and 31). Wood Framing: No. 1-29, Materials Matter: Bringing Color Back to the Street, Applying the Principles: Design in Practice, Design Principles: Seven Secrets to Adding Value to Your Design, The Streetscape: Designing an Outdoor Room, Reacting to Design: Getting to the Heart of the Issues, The Balancing Act: What Makes a Great Design, James Hardie's Commitment to Developing and Building Sustainably. Width: Plus or minus 0.5 percent or plus or minus1/4 inch (6 mm). The bottom edge of the first plank overlaps the starter strip. Position vent holes toward outside of eave for optimal airflow. Product: 5/4 Boards, 7-1/4 inch (184 mm) width. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. Minimum 1-1/2 inches (38 mm) face and straight, true, of uniform dimensions and properly aligned. Match touch up color to siding color through use of manufacturer's branded touch-up kits. If framing preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. Topcoat: Refer to Section 09 90 00 - Painting and Coating and Exterior Finish Schedule. Wood Framing: 0.091 inch (2.3 mm) shank by 0.225 inch (5.7 mm) head by 1-1/2 inches (38 mm) corrosion resistant siding nails. Panels may be notched and cut to size to fit between windows, doors, corners, etc. Inside Corner Trim: Aluminum extrusion to be used for inside corners. When installing horizontally, a WRB with min. Enter your zip code at www.hardiezone.com to find out what zone applies to your location. Type: HardieShingle Staggered-Edge Notched Panel 48 inches (1219 mm) wide by 16 inches (406mm) high with 7 inches (178 mm) exposure. Additional framing may be needed to ensure proper fastening. Substrate: Install a minimum 7/16 inch (11 mm) thick OSB wall sheathing or equivalent braced walls complying with applicable building codes. Apply planks horizontally with minimum 1-1/4 inches (32 mm) wide laps at the top. One person should hold planks on edge in the middle with arms spread apart for maximum support of the product Two people should always carry panel products. Fiber-cement siding - complies with ASTM E 84 Flame Spread Index = 0, Smoke Developed Index = 5. Type: Textured Cedarmill vented, 24 inches (610 mm) by 8 feet (2438 mm). Low Profile 45 degrees Inside Corner Trim: Aluminum extrusion to be used for bay windows. LENGETAS DE SUJECIN OCULTAS Para aplicaciones en esquinas, tablas de banda, ventanas y puertas: Las tablas HardieTrim pueden ser instaladas con lengetas planas (n de sku JH 280154) y lengetas de esquina (n JH de sku 280155) para brindar una sujecin oculta. James Hardie Building Products provides installation /wind load information for buildings with a maximum mean roof height of 85 feet. Market:Default | Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. Install soffits to nominal 2 x 4 framing members spaced a maximum of 24 inches (610 mm) on center with the long dimension perpendicular to the rafter or joist framing. Install a water-resistive barrier is required in accordance with local building code requirements. Minimum fastener guide for finish nailing: Store flat and keep dry and covered prior to, may result in shrinkage at butt joints. Product: 5/4 Boards, 5-1/2 inch (140 mm) width. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. Tested in Accordance with ASTM E136: Classified as non-combustible. Texas Department of Insurance Product Evaluation EC-55. manufactured by the Hatschek process and cured by high pressure steam autoclaving. Apply subsequent courses horizontally with a minimum 10 inch overlap at the top and a minimum 2 inch (51 mm) side lap. Finish warranty includes the coverage for labor and material. x 3.5 in. Water Tightness: No drop formation; Pass. Product: 5/4 Boards, 9-1/4 inch (235 mm) width. Fiber cement lap siding, panels, shingle, trim, fascia, moulding, and accessories; James Hardie HZ10 Engineered for Climate Siding and Hardie Architectural Panels. Minimum 20 gauge (1 mm) 3-5/8 inch (92 mm) C-Stud 16 inches maximum on center or 16 gauge (1.6 mm) 3-5/8 inches (92 mm) C-Stud 24 inches (610 mm) maximum on center metal framing complying with local building codes, including the use of water-resistive barriers and/or vapor barriers where required. Type: Beaded Smooth 8-1/4 inches (210 mm) with 7 inches (178 mm) exposure. Place fasteners no closer than 3/4 inch (19 mm) and no further than 2 inches (51 mm) from side edge of trim board and no closer than 1 inch (25 mm) from end. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest smoking may increase these risks. Type: Smooth vented, 12 inches (305 mm) by 12 feet (3658 mm). Type: Sierra 8 inches (203 mm) Vertical siding panel 4 feet by 9 feet (1219 mm by 2743 mm). Store sheets under cover and keep dry prior to installing. Product: 4/4 NT3 Boards, 5-1/2 inch (140 mm) width. Type: Smooth 5-1/4 inches (133 mm) with 4 inches (102 mm) exposure. There are many advantages of using HardieTrim NT3 boards including longer 12 lengths that reduce seams and speed up installation, back grooves that improve handle-ability and reduce weight, and a patent-pending concealed fastening system the reduces nail holes while improving overall aesthetics. Type: Hardie Architectural Knockdown Panel 4 by 10 feet (1219 by 3048 mm). Utilice cortes de burlete inclinados hacia el exterior para unir (fig. 2). Maintain clearance between siding and adjacent finished grade. Use a 2" finish nail to fasten trim together. Finish Warranty: Limited product warranty against manufacturing finish defects. Type: Smooth 9-1/4 inches (235 mm) with 8 inches (203 mm) exposure. Las esquinas tambin pueden ser prefabricadas (fig. Maintain clearance between trim and adjacent finished grade. 3). Type: Hardie Architectural Multi-Groove Panel 4 by 10 feet (1219 by 3048 mm). Type: Smooth 8-1/4 inches (210 mm) with 7 inches (178 mm) exposure. Type: Hardie Architectural Panels - Fine Sand 4 by 10 feet (1219 by 3048 mm). Fiber-cement trim - complies with ASTM E 84 Flame Spread Index = 0, Smoke Developed Index = 5. Specific framing and fastener requirements refer to Tables 2 and 3 in National Evaluation Service Report No. Apply starter course of 10 inches (254 mm) shingles or 9-1/2 inches (241 mm) lap siding overlapping the starter strip. If large areas require touch-up, replace the damaged area with new pre-finished siding. Install over braced wood. 8-18 by 0.311 inch (7.9 mm) head self-drilling, corrosion resistant S-12 ribbed buglehead screws. Remodel mock-up area as required to produce acceptable work. 90-100, Products Installation Guide_HardiePlank pg. Trim inside corner with a single board trim both side of corner. INSTALLATION - HARDIEPANEL HZ10 VERTICAL SIDING. Figure 28 BAND BOARD A ashing is required over the trim and Flat Tabs. Type: Beaded 8-1/4 inches (210 mm) with 7 inches (178 mm) exposure. James Hardie products stored in their original packaging. Finish factory primed siding with a minimum of one coat of high quality 100 percent acrylic or latex or oil based exterior grade paint within 180 days of installation. Type: Textured Cedarmill, 24 inches (610 mm) by 8 feet (2438 mm). Product: 5/4 Boards, 11-1/4 inch (286 mm) width. Type: Hardie Architectural Multi-Groove Panel 4 by 12 feet (1219 by 3658 mm). CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. Product: 4/4 NT3 Boards, 3-1/2 inch (89 mm) width. Factory Finish Color for Trim, Soffit and Siding Colors: EXAMINATION IMPORT "http://www.arcat.com/gfx/csi_revision_21b.gif" * MERGEFORMAT \. Slo las lengetas planas y de esquina pueden ser utilizadas con tablas HardieTrim para crear una sujecin oculta. Fastener Positioning: Position fasteners 3/8 inches (9.5 mm) from panel edges and no closer than 2 inches (51 mm) away from corners when using soffit greater than 12 inch (305 mm) wide and no closer than 1 inch (25 mm) away from corners when using soffit that is less than or equal to 12 inch (305 mm) wide. B). HardieTrim HZ10 boards as manufactured by James Hardie Building Products, Inc. Alternatively corners can be pre-built (fig. Factory Finish Touch Up: Apply touch up paint to cut edges in accordance with manufacturer's printed instructions. Follow paint manufacturer's written product recommendation and written application instructions. Touch-up, repair or replace damaged products before Substantial Completion. Type: Select Cedarmill 6-1/4 inches (159 mm) with 5 inches (127 mm) exposure. For further information, refer, to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE (1-800-942-7343). Low-Profile Inside Corner Trim: Aluminum extrusion to be used for inside corners. Use touch-up paint sparingly. CAL-FIRE, Fire Engineering Division Building Materials Listing - Wildland Urban Interface (WUI) Listed Product. Wood Framing: 0.089 inch (2.2 mm) shank by 0.221 inch (5.6 mm) head by 2 inches (51 mm) corrosion resistant siding nails. 8-18 by 0.323 inch (8.2 mm) head self-drilling, corrosion resistant S-12 ribbed buglehead screws. WARNING: AVOID BREATHING SILICA DUST James Hardie products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational sources. For additional information on HardieWrap W, - NEVER use a circular saw blade that does not carry the HardieBlade, - NEVER dry sweep Use wet suppression or HEPA. Product: Batten Boards, 2-1/2 inch (63 mm) width. Install kickout flashing at roof-wall junctions per manufacturer's instructions. N-95) in accordance with applicable, government regulations and manufacturer instructions to further limit respirable silica exposures. Texas Department of Insurance Product Evaluation EC-23. Wind speed design coefficient assumptions per Analytical Method in ASCE 7. US Department of Housing and Urban Development Materials Release -1263. Hardie Architectural Panels for 30 years. 4/4, 5/4 Boards EFFECTIVE SEPTEMBER 2013 Visit www.jameshardie.com for the most recent version. Fasten maximum 16 inches (406 mm) on center. Product Warranty: Limited, non-pro-rated product warranty. Florida State Product Approval -FL13192, FL13223, and FL13265. Factory applied finish by fiber cement manufacturer in a controlled environment within the fiber cement manufacturer's own facility utilizing a multi-coat, heat cured finish within one manufacturing process. Type: HardieShingle Individual Shingles 6 inches (152 mm) wide by 18 inches (457 mm) high with 8 inches (203 mm) exposure. Installed on flat vertical wall applications only. Wood Framing: 0.121 inch (3 mm) shank by 0.371 inch (9.4 mm) head by 1-1/4 inches (32 mm) corrosion resistant roofing nails. 2). Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6 in. 2022All rights reserved Cuando utilice clavos de revestimiento, fije la presin del aire para que el sujetador quede ajustado con la superficie del revestimiento (il. Wood Framing: 16 gauge 1-1/2 inches (38 mm) stainless finish nails. These products must be kept covered on a pallet off of the ground; they must never be stored in direct contact with the ground. 13 y 14). ASTM E84: Surface Burning Characteristics. Product: 4/4 Boards, 5-1/2 inch (140 mm) width.