Replace the drain plugs on start-up. If you are installing your tub with custom decorative trimming, remember to allow for access to it for service. Pregnant or possibly pregnant women should limit spa water temperatures to 1000F (380C). The system has shut the heater off because the temperature at the heater has reached 1220F (500C). To increase PH, use a pH Up/lncreaser (sodium hydrogen carbonate). KEEP CLEAN: Prevent dirt and foliage from being tracked into your spa by utilizing concrete for paths and access areas. TO REDUCE THE RISK OF INJURY: The water in the spa should never exceed 1040F (400C). Do not enter the water! Equipment access is below the Topside Control Panel on Plug & Play LifeSmart Spas. Let filter dry and look for calcium deposits (scaling) or an oil film. Remove the equipment compartment access door. Call customer service at (888) 961-7727 Ext. Using the shop vac, remove the water starting with the jets at the top and moving downward. If the reading requires adjustment, it should now be corrected. Attempt to open the electrical control box. Never let the spa pump run without a filter cartridge in the skimmer compartment. A GOOD FOUNDATION Your new spa needs a good solid foundation. To program the cycle times: 1. Never scrub the filter cartridge with a brush, as this will cause the filter to wear out and come apart. An extension cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor damage. 5. 4. The default duration for the first filter cycle is 1 hour, and 30 minutes for the second cycle. Using a funnel, pour Propylene glycol anti-freeze into the filter suction fittings and jet outlets. Contrary to some information circulated throughout the pool and spa industry regarding ozone systems, ozone CANT be used as a single-source sanitizer, water clarifier, anti-foamer, and mineral chelating agent. Thoroughly dry the spa shell with a clean towel. The function of the diverter valve can best be learned by experimentation. CAUTION! Sitting in this area can cause: a) Restriction of Filter Pump suction/vacuum b) Damage to components Both can result in bodily harm. Check the filter installation and make sure the filter is not loose. If left running the low or high speed pump will automatically turn off after 1 hour. For example, will you use it more for recreational or therapeutic purposes? It flashes when there is a request for more heat. NOTE: If left on, the light will automatically turn off after 4 hours of operation. If you are not able to resolve the problem, contact customer service at (888) 961-7727 Ext. 6. 6, ****** Page 10 ****** EQUIPMENT ACCESS EQUIPMENT ACCESS PANEL Topside Control Panel Slat Slat Screw Equipment Access Panel Door Hose Bib Electrical Recess & Drain Hose Foam Door To access the equipment compartment: Remove 1 vertical slat and screws on each side of Equipment Access Panel Door (on some spas). 230 VOLT, PERMANENTLY INSTALLED MODELS: A ground terminal is provided on the control box. The circuit breaker must be dedicated and should not be shared with any other appliances. 5. With the help of a second person, block off any suction from the other jet using a large rag or cloth. All wiring must be copper to ensure adequate connections. 4. 8, ****** Page 12 ****** ELECTRICAL REQUIREMENTS 8. Rotate the air control to the max position. Firmly press the Jets (1) button again to turn off the pump. This will not be covered under warranty. Your spa must have a ground fault circuit interrupter in an electrical subpanel. Read instructions on cleaning products and follow applicable safety and warning instructions listed on label. 3. 8440. Be certain your installation will meet all city and local safety codes and requirements. To remove the LED, turn outside housing counter clockwise 1/4 turn, and pull out and remove LED from socket. If the foundation is inadequate, it may shift or settle after the spa is in place, causing stress to the shell or components. There are certain precautions to keep in mind when draining your spa. If this occurs, repeat the GFCI test procedure. HYDROTHERAPY JETS The hydrotherapy jets are recessed in the wall of the spa. The use of an extension cord or a disconnectable power cord is highly dangerous and will void all warranties! 2. 3, ****** Page 7 ****** SAFETY INFORMATION AVOIDING THE RISK OF HYPERTHERMIA Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs when the internal temperature of the body reaches a level above normal 98.60F (370C). Turn the air controls off when the spa is not in use, this will prevent cold air from entering the spa and will keep heating cost to a minimum. FILTER CYCLES There are two filter cycles: the first cycle (F 1) starts right after power up and the second cycle (F2) will start 12 hours later. If 1 is yes and 2 and 3 are no contact customer service for service. Most cities, counties, states, and countries require permits for exterior construction and electrical circuits. 3. To lower the pH use a pH Down/Decreaser (sodium bisulfate). Do not use aluminum wire. NOTE: Tighten unions before filling spa. Clear all the debris from your spa. Learn how your comment data is processed. Wait 30 seconds and reset the GFCI breaker by switching it completely off and then completely on. Check for a diagnostic Message (see Control System manual for details) OH Overheat (spa is deactivated) DO NOT ENTER THE WATER. SLEEP MODE: Water sampling and heating is only done during the filter cycles while trying to bring the spa water up to the set temperature. After checking your spa for leaks it is now time to adjust your spa settings. Power has been cut off to the spa. The ozone jet (when equipped), will always produce air bubbles. Shocking is achieved by adding the MPS to turbulent water. Make sure all jets are in the open position. While the pump is running, leaks may have occurred during transit. Consider the view of your neighbors when you plan the location of your spa. Additionally, failure to keep enough water in your spa may result in damage to your system & invalidate your warranty. Many problems can easily be diagnosed over the telephone by an Authorized Service Technician. Supply lines must be properly sized as per the NEC (National Electric Code). If you need additional information and/or assistance, please contact Customer Service at (888) 961-7727 Ext. Contact Customer Service or a reputable spa service company for assistance. 2, ****** Page 6 ****** SAFETY INFORMATION Place electrical appliances within 5 feet (1.5m) of the spa. NO USER SERVICEABLE PARTS. NOTE: Never run your spa without a filter cartridge!!! WARNING! If you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions. Push down slightly and turn filter basket counter clockwise to unlock, then pull the basket and weir out. If the spa water temperature continues to rise and gets above 1080 F (420C), the spa will go into an OH overheat condition. 4. Remember that wet surfaces can be very slippery. 2. 8440. Follow all owner manual power connection instructions. CABINET CARE Little maintenance is required to keep your spa cabinet looking good. DO NOT use extension cords of any kind this will invalidate your warranty. Hot soapy water is the best choice for cleaning your spas cabinet. 2. JETS OPERATION 230 volt models: Firmly press the Jets (1) button once to activate the low speed of the pump and again for the high speed. Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using spa. Remove the floating weir, basket, and filter cartridge. Spa settings will be preserved until next power up. This site uses Akismet to reduce spam. For example, you may need to prevent direct sunlight on any surface of your spa. WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. OFF MODE: This mode allows you to stop all spa functions for 30 minutes to perform quick spa maintenance To place the spa in OFF MODE, press and hold the Jets (1) button for 5 seconds. These documentations are only intended for a qualified person who is aware of the respective safety regulations and hazards. IMPORTANT: To reset the first filter cycle start time, skip step 5 and continue pressing the Light button until the actual temperature is displayed. Please follow the four steps below and be sure to achieve the correct levels in each area before moving onto the next step. WEEKLY SHOCK: Using a potassium monopersulfate (MPS) shock, add approximately 2 oz. If unsure about any step in the process, please contact a Customer Care Associate at (888) 961-7727 Ext. Attempt to open the electrical control box. Consider placement of trees, shrubs, patio cover or perhaps a gazebo structure to provide what you will need. After adding a teaspoon, wait one half hour before re-measuring. Different codes will display on the screen. Above 7.8, the water is too alkaline and can result in cloudy water, and scale formation on the shell and heater. SPECIAL CIRCUMSTANCES: The use of a crane for delivery and installation is primarily to avoid injury to your spa, your property or to delivery personnel. Lift or drag the cover by using the cover lock straps; always lift or carry the cover by using the handles. 4. Then shut jets off and return the cover to the closed position to maintain heat. STANDARD MODE: Is programmed to maintain the desired temperature with periodic water circulation (sampling) to sample and heat the water to the set temperature. 17, ****** Page 21 ****** SPA MAINTENANCE FILTER CARTRIDGE MAINTENANCE Every month, the filter cartridge should be cleaned to remove the objects and particles that have lodged in the cartridge pleats. Use an 8 AWG solid copper wire and attach it to the grounding lug on the power pack, located in the equipment compartment. 8440. Extreme caution must be exercised to prevent unauthorized access by children. iron) are present in the local source water. Never operate spa if the suction fittings are broken or missing. This moisture can damage walls and ceiling surfaces over time. Service must be performed by a licensed electrician and all grounding connections must be properly installed. It is always best to design special installations so the spa can still be moved, or lifted from the ground. Your spa has been designed so that it will automatically heat the water to the factory set temperature of 1000F (380C) unless you set the spa to a different temperature. Clean, if necessary. FILTER CARTRIDGE REMOVAL AND CLEANING INSTRUCTIONS Spa uses a screw in filter cartridge that is easily removed. Note: The air control valve and the waterfall flow valve may look exactly the same, however; they are separate components. Click to share on Twitter (Opens in new window), Click to share on Facebook (Opens in new window), Click to share on WhatsApp (Opens in new window), Click to share on Telegram (Opens in new window), Click to share on Pinterest (Opens in new window), Click to share on LinkedIn (Opens in new window), Click to share on Tumblr (Opens in new window), Click to share on Skype (Opens in new window), Click to share on Reddit (Opens in new window), Click to share on Pocket (Opens in new window), Click to email a link to a friend (Opens in new window). Replace filter cartridge, then return basket and weir, insert and rotate clockwise to lock into position. 20, ****** Page 24 ****** TROUBLESHOOTING PROCEDURES In the event your spa is not working the way it should, please first review all the installation and operating instructions in this manual and check the message on the panel display. Disconnect the power until the problem has been corrected. Depending on your spa model you will either have a one pump or two pump control panel as illustrated. Do not enter the water! Turning a jet on or off will increase or decrease the effects of any jets not in the closed position. House Breaker BOX OFF ON OFF OFF ON ON OFF ON (HOT) OFF ON GRS aoaoaoaoaao G.F.C.I. Plug the spa into the 15 amp dedicated, grounded wall outlet, or turn on power from Main Panel and 230V Sub Panel. DIAGNOSTIC LCD MESSAGE COMPONENT OPERATION SPA COMPONENT OPERATION FILL UP AND START-UP INSTRUCTIONS FILLING THE SPA WITH WATER .6 .. 10 .11 12 14 .. 15 16 APPLYING POWER 16 CABINET CARE SPA LED LIGHT REPLACEMENT 19 DRAINING OR WINTERIZING DRAINING YOUR SPA 20 WINTERIZING YOUR SPA. SAFETY SIGN A SAFETY SIGN is in the owners package. Make sure the water level is at least 2 (5 cm) above the gray filter ring. If draining for the first time. IMPORTANT: Under NO circumstances should an extension cord be used. Remove the cover when adding chemicals to your spa. Do not bury the power cord. Press the Light button several times until F or C is displayed. Every time the light is quickly turned off and on a new light mode will appear. Install your spa in such a way that drainage is away from the electrical compartment and from all electrical components. 4. If it is extremely cold, and the spa is outdoors, freezing could occur in the plumbing or the equipment. Press the JETS button several times, never leaving the motor on for more than 5-10 seconds at-a-time, if prime is still not achieved, loose unions (pg. In addition, some communities have codes requiring residential barriers such as fencing and/or self-closing gates on the property to prevent unsupervised access to a pool or spa by children. 2. NOTE: This will reset the filter cycle. Locate the rear of the spa light. TEMPERATURE ADJUSTMENT Lights life$sma Je s Light 2 Pump 9 Jets 1 Temp Up Temp Down Indicator Lights Ifepss art Light Temp Up/Down Jets 2 The temperature can only function between 800F 1040F (26.50C 400C). Contact Customer Service for assistance. Extended use can cause hyperthermia. CAUTION! As the water level rises, check inside the equipment compartment for water leaks. Below 7.0 (considered neutral), the spa water is too acidic and can damage the heating system. Rotate the bezel of the Turbo Jet to open or close the flow of water from the jet. People with infectious diseases should not use the spa. STEP ESTABLISH PROPER PH LEVEL: The recommended range for pH is between 7.2 and 7.8. Press the Plus or Minus button to adjust the cycle time for F2. Water will accumulate around the spa, so flooring materials must provide a good grip when wet. Follow the Fill up and Start-up Instructions. PUMP DOES NOT OPERATE, BUT THE LIGHT ICON DOES .21 POOR JET ACTION WATER IS TOO HOT .18 19 .. 19 ..21 21, ****** Page 4 ****** SAFETY INFORMATION IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS AVOIDING THE RISK TO CHILDREN DANGER: RISK OF CHILD DROWNING. 5. Rotate the jet face one direction or the other to turn the jets on or off. There is a danger of slipping and falling. DO NOT use extension or plug- type cords of any kind. DANGER: RISK OF ELECTRICAL SHOCK Install spa at least 5 feet (1.5 m) from all metal surfaces. This will provide a better understanding of how to treat the water. Never use compressed sanitizers even with a floater. To reduce the risk of electric shock, connect this terminal to the grounding terminal of your electrical service or subpanel with a continuous green, insulated copper wire. Always use proper eye protection when using chemicals, or high-pressure water. Use an extension cord to connect the spa to its power source. A WARNING! SURFACE CARE COVER CARE. ECONOMY MODE for LS700DX: This mode allows you to lower the temperature set point of the spa by 200F (1 IOC), to change to the Economy Mode press and hold Light button for 5+ seconds until Fl is displayed. WARNING: To reduce the risk of electrical shock, replace a damaged cord immediately. Pull the hose bib out a few inches from the spa (located in the recess under the spa, just below the equipment access door). Breaker Box Front Vietc of G.F.C.I. The GFCI power indicator will turn on, restoring power to the spa. 6. The Jets indicator light above the button will blink when the jet pump is on low speed and is solid on high speed. The Heat indicator lights up when heating. Remove screws from Foam Door (if your spa has vertical slats and partial access panel door) to access Equipment Compartment. Installations within 5 feet (1.5 m) of any metal surfaces must ground the metal surfaces to the hot tub. Special Note: If the GFCI Breaker trips immediately after attempting to turn on, please check the White Neutral Wire that is connected to the Spa.