Add your voice! 10 0 obj Also, we found that when the smoke didn't go up the chimney it was time to clean the chimney. No moving parts. The 3-4 inch pipe motors have a fixed speed at 50 CFM and are hardwired or you can insert (hardwire) a plug pigtail in them. Auto-Draft Blower for Wood Burning Stoves. ThriftyFun is powered by your wisdom! We have our stove pipe going through the wall to the outside of the house like 12 inches or so. There is a larger DRAFT INDUCER FAN available for another $75 add-on charge for larger stoves, furnaces, and boliers where where the BTU Input is 100,000 BTU/Hr to 330,000 BTU/Hr. Maintains 400 degrees inside the flue pipe to induce draw. Specify your pipe size when ordering. height or diameter of the chimney. For 5-8 inch pipe motors in solid fuel (pellets, wood logs, coal), you can adjust the variable speed control kob on the electrical box to achieve the maximum effectiveness of your stove. This larger unit is hard-wired into the electrical and has a fixed 75 CFM speed and has no knob-adjustment feature. i have also heard that if you put the pipe about 2 feet above the peak that helps to. The variable speed on your 5-8 inch Pipe Motors for solid fuels can be adjusted from 30 to 350 CFM of Flue gases, and if your stove is power vented, then you can adjust the speed of the Draft Inducer to match the speed of your stove flue fan. Pipe sizes range from 3 to 8 inches and you cut an elongated square hole in the pipe and strap it onto the pipe together with high temperature silicone caulk. If the draft inducer motor fails or there is a blockage in the chimney, the vacuum inside the inducer housing is lost, thereby opening the circut and shutting off the gas or oil-fired burners. It is used in commercial buildings or breezy residential houses or apartments. The pigtail corded outlet is also hardwired into the unit. The Auto-Draft can be installed on any wood or coal burning stove pipe 5" to 8" We sell both of them and see them in our Ebay store Wood, Coal, and Oil burning stoves that use a 6 to 8 inch flue exhaust pipe may wish to use a Barometric Draft Regulator either with, without, or instead of a Draft Fan Inducer. % and the pipe sizes are 5,6,7,8 inches in diameter. NOTE: For double-walled pipe such as corn and wood-pellet TYPE L Pipe (3 to 4 inches) for corrosive burning appliances, after you cut the hole insert, around the hole-insert perimeter, you must fill the wall GAP with one of the following three: (1) Fiberglass-Mesh Rope (used for doors); or (2) HIGH TEMPERATURE SILICONE CAULK and/or (3) CERAMIC WOOL. For oil and gas fired systems, the 5-8 inch Pipe Motors will be hardwired at a fixed speed. When ordering specify (1) your pipe size; (2) type of fuel e.g. The pipe then makes a right angle then goes up many feet to above the roof line. /Filter /FlateDecode draws immediately. Not applicable for coal, wood-log stoves, optional for wood-pellet stoves. You could try opening the controls about half a turn or so for a few minutes before opening the door to load. If ordering 5-8 inch size fan be sure to specify size, fuel, and BTU output (estimate). Prevents reverse draw when fire dies down. It creates immediate draft or induces a draft in hard-starting wood stoves Smoke back-up problems? most cases. Burn ALL your wood, even moist or hard-to-burn types of wood, and reduce it to small ash residual in most cases. >> {o]&0bnQ1@ZAw,t0f^o f2"z a-u5 m Prevents reverse draft. Shipping is by either by USPS, Fedex, or UPS, weight is 10 lbs with the package weight at 15 lbs. they say that the wind helps the draft. Fits Most Wood or Coal Burning Stoves Check out our other Corn Stove items listed in our Ebay Store. If required add $150 or call for a special Ebay buy-it-now listing to avoid circumventing of Ebay fees. All components are High Temperature rated. This will get the heat going up the chimney taking the smoke along with it. 4' Power Cord included. Increases burn efficiency. << 110V / 500W, High temperature Satin Black Powder Coat finish. *** SEE VIDEO ***, DRAW COLLAR Wood Stove Draft Inducer Features, Plugs into a standard 3-prong outlet. HWrFCW%27JlnIBR_ $a+o 7"m9qU29}7pa`cC>0:]|~7wwb=6-~PG`gV[a'~tv7.b[7[T!01\Wnp3olZ&sW04i~:Hsa No smoky back up--even with moist or hard to ignite types of Once the fire is burning, adjust the variable speed control knob on the Pre-Heats Chimney Flue. FOR CORN, WOOD-PELLET, AND WOOD LOG STOVES w 3 to 8 INCH PIPEFIXED SPEED 50 CFM and ADJUSTABLE SPEED for 30 to 350 CFM. It can be used for any kind of stove such as wood, oil, coal, or even pellet stoves such as wood pellets or corn. Does anyone know how to make up a draft inducer for a wood burning stove to help keep smoke from coming into room when you feed the stove?mickey2. All Rights Reserved. Removing Black Soot from a Wood Stove Window, Use a Pool Noodle and Socks to Make a Draft Stopper. DRAFT INDUCER FAN FLUE EXHAUST Wood, Pellet, Corn, Coal, Oil, Gas Stove Furnace, AUTHORIZED DEALER with Quality and Service,  DRAFT INDUCER FAN for FLUE EXHAUST GASES, FOR CORN, WOOD-PELLET, AND WOOD LOG STOVES w 3 to 8 INCH PIPE. A Barometric Draft Regulator will maintain consistent draft by counteracting the negative forces caused by changes in temperature, barometric pressure, and effects of the wind. We twist off this cap and put a piece of twisted newspaper in which is on fire. Low Profile. I hope you have a "Damper" on your stove pipe,that's what controls the heat in your stove plus it helps to keep the smoke down when the door is opened. OIL and GAS FIRED SYSTEMS: National and local building codes are now requiring a FAN PROVING SWITCHColor=green> be installed with the Draft Inducer Motor on gas and oil-fired stoves and furnaces. Contact your local municipal code department, local HVAC suppliers, or you can call us to see what we are recommending. Made in the U.S.A. Dimensions 7-1/2 x 8-1/2 x 11-5/8 inches, weight 15 lbs, used for 3 thru 8 inch pipe, Pipe GAP Filler (caulk or ceramic wool) available, shipping weight 15 lbs. It is designed to solve draft problems without increasing the Extra Cost is $145.00. The way it works: a cover damper plate will crack open and allow room air to come into the flue pipe system to balance out the air pressure (or vacuum). The 3-4 inch pipe motors do not come with an adjustable speed control knob but are instead at a fixed speed of 50 CFM and are hardwired or you can buy a pigtail cord outlet for it for $15.00 plus $7.50 shipping. 3-4 inch Pipe Motors have a fixed speed at 50 CFM and are hard-wired, 5-8 inch Pipe Motors for solid fuels have a Variable Speed 30 to 350 CFM and the oil/gas fuels are Hard-wired at 50 or 75 CFM, 1 Amp Motor at 110 VAC with 60 Hz. At the bottom of this pipe, ground level, is a cap which can be unscrewed. Provides maximum draft on Fire Start. stream Ask about an ADAPTOR that can be made for 3 and 4 inch corn and wood pellet stoves. Where is the best place to install your damper? Completely silent. With the Auto-Draft your hard starting stove Boost your Flue Exhaust Gases with this DRAFT INDUCER FAN. wood. Yo~?yf:YBY8RmWU*a~8.av9 oP Dx(,KF2v,#Z2m?%Hj|m9 ge4g8g&.a1 `Y(t~YRlV_I!d1b&hG,Mjo&Qi}V0WC5wq% U( DDyQ. just before opening the door,open your damper all the way,should be straight up and down,when you are finished loading,and until the fire is going good,leave it that way. and is hard-wired at fixed speed of 75 CFM. electrical box to achieve the maximum efficiency of your stove. Fiberglass-Mesh Rope is the best alternative. The Auto-Draft Room to Room Ventilation Fans - Tjernlund, Commercial Capacity Dryer Duct Booster Fan, Compact High Velocity Destratification Ceiling Fan, FAI4 Powered Fresh Air Intake Fan Kit with Hood. Double-walled pipe must have the air gap filled around the hole insert with fiberglass-mesh rope gasket (used for doors). Click below to answer. specify (1) your pipe size; (2) type of fuel e.g. Try opening a window a little to get some air FOR a draft moving into the house, don't forget that if you have an energy efficient home it is fairly air tight and there will be insufficiant air flow to create a draft. I use a propane torch or kerosene "salamander" heater with the damper closed, to fill the stove with heat for a minute or so, the open the damper and the heat will rise and draft will start up. %PDF-1.2 Disadvantage is it uses fresh air or heated air in the room and the room has to have availble air to feed it. Normal BTU/Hr input is 100,000 BTU/Hr or less; a larger Fan is available for oil/gas fired systems at BTU/Hr Range of 100,000 to 330,000 BTU/Hr. Remember to check our Ebay Store for other related items. in diameter. It takes up to 1 amp at 110VAC and is hardwired into your electrical general circut or into your stove turn-on circut. then eliminate them with this Draft Fan Inducer. When mounted on the pipe, the air paddle blades or vanes extend into the pipe about 2 inches. Tight buildings will probably need a Fresh Air Kit to supply air. pellets, wood logs, coal, oil, gas; (3) BTU Output (estimate) of your stove, insert, or furnace; OIL and GAS FIRED SYSTEMS: National and local building codes are now requiring a, ANTIQUE LOGCABIN COAL WOOD STOVE, New, QUEEN ANNE LEGS, Manufactured Replica, CAST TECH WOOD LOG STOVE burns LOGS and WOOD PELLET, Cast Iron ANTIQUE Replica, CENTURY TURN WOOD LOG and PELLET STOVE, LARGE, 123,000 BTU, FLUE EXHAUST REAR MOUNT, Multi-Fuel, Negative Pressure, WOOD LOG FIREPLACE INSERT ANTIQUE REPLICA COLONIAL NEW, HOT WATER HEATING COIL for STOVES burning Wood Pellets, Corn, Coal, Wood Logs, ACCESSORIES Corn & Wood Pellet Stoves, Inserts, WINCHESTER MAGNUM FIREPLACE INSERT, WIN-ACI, burns CORN, PELLETS, MULTI-FUEL, 45-50,000 BTU/Hr, WOOD PELLET MOISTURE TESTER STOVE FURNACE BOILER, Jumbo Wood Pellet Stove Furnace,55,000 BTU, 350lb Hoppr. provides for total utilization of your wood, leaving only a fine ash residue in Copyright 2014 REWCI.com. The WARRANTY on this unit is 1 YEAR or a 12 month limited warranty. Unless otherwise stated and requested , the 5-8 inch pipe motors for solid fuels will have a variable control adjustment knob and the oil/gas fuels will have hard-wired at a fixed speed either 50 CFM or 75 CFM.. Heating, Air Conditioning, Ventilation and Air Distribution Products. /Length 11 0 R For proper operation and efficient fuel consumption, wood, coal, and oil fired furnaces must have a constant draft. 0u"|'np4bbaE`Mt08# f7x-(I W7 1w5Mg`8o` pellets, wood logs, coal, oil, gas; (3) BTU Output (estimate) of your stove, insert, or furnace; Color=red>.